RE:[sap-log-sd] Error Number Range for Trans/Event Type WL in Year 2012 Does Not Exit

Reply from HarshaHalyal on Jan 24 at 2:33 AM
Hi ITSMEPRIYA,

Go to OMBT T-code and press on Groups Select the group that contains the event type in question. In this case it is "WL" and hit edit. Select 2011 and go to edit in menu and select insert year. And create new number range for 2012.

Reply me if I am wrong.
Harsha Halyal

---------------Original Message---------------
From: itsmepriya
Sent: Sunday, January 22, 2012 9:35 AM
Subject: Error Number Range for Trans/Event Type WL in Year 2012 Does Not Exit

Dear All,

While creating PGI one error is came "Number Range for trans/event type WL in year 2012 does not exit.

Also, I have checked OVA7 all are ok. Kindly give me suggestion.

Regards,
P. Mohapatra

 
Reply to this email to post your response.
 
__.____._
Manage Settings | Unsubscribe | Create FAQ | Send Feedback
  
Copyright © 2012 Toolbox.com and message author.
Toolbox.com 4343 N. Scottsdale Road Suite 280, Scottsdale, AZ 85251
HarshaHalyal  
Mr
achievements
 
Mark as helpful
View this online
Ask a new question
 
In the Spotlight
Become a blogger at Toolbox.com and share your expertise with the community. Start today.

_.____.__